How to Choose the Right Concrete Placing Boom Radius?
When choosing a concrete placing boom, many people choose a radius based on the approximate size of the floor slab. When they arrive on site, they may find that the boom does not reach the corners, or there is not enough room to unfold it fully.
Don’t look at the equipment parameters first when selecting the model. Take the construction plan first and mark out all the candidate points where the placing boom can be set up. On the same floor, the required placing radius will vary depending on whether the placing boom is set up in the center of the floor, along the edge of the slab, or at the corner of the building. All subsequent distance measurements should start from the marked center of rotation.

What Exactly Does the Placing Radius Mean?
The placing radius refers to the horizontal distance from the placing boom’s center of rotation to its discharge point. Use the manufacturer’s working range diagram to determine the actual reach limits.
Many on-site personnel can easily confuse several parameters. The total length of the boom and the length of the whole delivery pipeline are not equal to the placing radius. The pipeline follows the bends of the boom, and its length cannot be used as a measure of horizontal reach.
The maximum placing radius listed in the manufacturer’s specifications can only be used as a starting reference for model selection. Even if the horizontal distance to the pouring point is less than the specified maximum radius, the boom may still be unable to reach that point on site.
On-site restrictions on slewing and boom articulation, as well as obstructions such as beams, columns, and temporary structures, can reduce the pouring area that the equipment can actually reach. Comparing the numbers alone can lead to selection mistakes.
How to Calculate the Placing Radius Actually Needed by the Project
Mark possible setup locations for the placing boom
Open the construction drawings and mark all the positions on the floor that meet the installation conditions. Identify the center of rotation for each candidate point, and take all subsequent measurements from this center point.
If you choose a mobile concrete placing boom, you should also check the load-bearing capacity of the supporting surface and the space around each point. Some locations look suitable on the drawings, but there is not enough room for the supports at the site, and the equipment cannot be set up there. Such points should be excluded.
Measure the horizontal distance to the farthest pouring point
For each planned pour zone, measure the horizontal straight-line distance from each candidate center of rotation to the outer corners of the floor slab, the slab edges, and any projecting parts of the building.
For each setup location, use the horizontal distance to the farthest pouring point as the starting point for selecting a placing boom.
Take a 24 m × 18 m rectangular floor slab as an example. The entire slab needs to be poured.
- If the placing boom is placed in the center of the slab, the required geometric radius to reach any corner is 15.0 m.
- If the placing boom is placed at the midpoint of the 24 m side, the geometric radius required to reach either of the two opposite corners is about 21.6 m.
On the same floor, just by changing the position of the placing boom, you can significantly change the required placing radius. If you encounter insufficient coverage, you can consider adjusting the location first before selecting equipment with a larger radius.
What is calculated on the drawing is only the horizontal distance, which is used to screen candidate models. Actual coverage still needs to be checked against on-site working conditions.
Check the Actual Working Coverage of the Placing Boom
Slewing range and on-site obstacle inspection
Superimpose the placing boom’s slewing range on the construction plan. Check whether the columns, building core, shear walls, other construction equipment, and temporary supports on site will block the boom’s path.
At some pouring points, the horizontal distance does fall within the maximum radius of the equipment. However, a wall or building core may block the boom’s path and prevent it from reaching those points. Checking distance alone can miss these blind spots.
Boom articulation and vertical clearance
Use the working range diagram issued by the manufacturer to see how much space the boom needs to unfold fully, fold, and slew.
If part of the structure is already in place above the floor, or if there is a height difference in the pouring surface, check the section drawings as well as the floor plan. Confirm that the boom clears existing structures as it rises and lowers. Insufficient vertical clearance can prevent the boom from reaching its full placing radius.
Check both near and far pouring points
Most people will only focus on the farthest corners of the floor to check the range. Blind spots can also occur near the base of the placing boom, in narrow gaps between walls, and next to obstacles.
Reaching the farthest point does not mean that the entire pouring area is covered. In some working conditions, the boom can reach distant points, but the way it folds can limit access near the base. Far and near points need to be reviewed one by one.
Choose a Model with a Larger Radius or Move the Placing Boom?
| On-site conditions | What to consider first |
| The installation position of the placing boom cannot be changed, and several distant areas are beyond the operating range of the existing equipment | Compare models with a larger placing radius and confirm whether there is enough room to unfold the boom and whether the supporting surface meets the requirements of the new equipment. |
| Only a few corners are out of reach, and other setup locations are available on site | Review the setup locations for the placing boom and compare the overall coverage from each one. |
| The building core and walls divide the floor into several separate pour zones | Follow the actual pouring order and assess whether the zones can be poured separately and whether the boom can be moved between them. |
| The horizontal distance meets the requirements, but structural elements restrict slewing or unfolding | Check the manufacturer’s working range diagram, compare models with different boom folding configurations, and re-evaluate the setup location. |
After completing all the distance measurements, compare the calculated horizontal distances with the manufacturer’s working range diagram, and check the key corners and edges of the pour area one by one.
For concrete placing boom models such as HGY14, HGY15, HGY17 and HGY21, a comparison table showing each model’s working range can help with preliminary selection. Use the floor layout, on-site obstacles, and available setup locations to select a placing boom that can be installed on site and cover all planned pour zones.