How to Clean the Concrete mixer Pump After Use?
After the operation of the concrete mixer pump, some concrete slurry will remain on the surfaces of the mixing chamber, the receiving hopper and the interior of the conveying pipeline.
If left unattended, the slurry will slowly harden over time. The hardened concrete is firmly attached to the inner surfaces of the equipment, and it is difficult to clean it in the future. It will also bring a series of troubles such as pipeline blockage and abnormal wear of parts.
Equipment cleaning can’t be done with just flushing the shell. The mixing mechanism, pumping components, and the whole conveying pipeline should all be taken into account. Next, in combination with on-site practical experience, we will talk about the cleaning process after the completion of the operation, the details that need to be paid attention to, and common operating mistakes that workers should avoid.
The Significance of Cleaning the Concrete Mixer Pump in Time after Use
Once the concrete remaining inside the equipment solidifies and clumps, it will accumulate in all corners of the cavity and along the pipe walls. The thicker the lumps accumulate, the more they will reduce the space for the material to pass. In severe cases, it will directly cause the pipeline to be blocked, and the whole set of equipment will not be able to deliver concrete normally.
Hard concrete lumps will also constantly bump and scrape the mixing blades and internal pump components. Many wear parts need to be replaced prematurely, not only due to normal operational wear, but also due to repeated wear and tear caused by internal residual hard blocks.
After blockages occur or parts are damaged, you have to stop for disassembly, repair and cleaning. The shutdown and maintenance not only delay the construction progress of the site, but also incur additional expenses for labor and replacement parts. Doing a good job of cleaning after each operation can reduce such unnecessary trouble.
Preparations Before Cleaning the Concrete Mixer Pump
Drain the remaining concrete inside as completely as possible.
As soon as the operation is finished, all the concrete that has not been poured out in the mixing chamber should be discharged through the normal discharge process of the equipment.
After the discharge, briefly check the mixing chamber and the receiving hopper to confirm whether there are large lumps of concrete inside. Don’t let a large amount of concrete stay inside the equipment for a long time. The shorter the waiting interval for cleaning, the better.
Prepare water sources, tools and protective equipment.
Connect the water supply pipe in advance to ensure that the amount of water supply can meet the flushing needs. Prepare tools such as shovels and brushes to scrape off semi-solidified lumps.
Prepare the pipe cleaning ball (sponge cleaning ball) or the pipe flushing accessories approved by the manufacturer according to the equipment manual, and do not use homemade substitutes casually. On-site personnel should also wear gloves and other basic protective equipment to avoid direct skin contact with slurry and wastewater.
Implement on-site safety procedures
Park the mixing pump on flat and stable ground, and put the stabilizers in place to prevent the equipment from shifting.
Complete the shutdown process in strict accordance with the equipment manual, cut off the power, and release the internal pressure of the pumping circuit. As long as there is still pressure in the pipeline system, do not disassemble the pipes and joints.
During the flushing process, if you need to start the equipment for a short time to assist with the flushing, your body and tools should not be close to the rotating mixing blades and the moving pumping mechanism to prevent injury.
Practical Cleaning Steps of the Concrete Mixer Pump
Step 1: Clean the mixing system
The concrete mixer pump has its own independent mixing mechanism, which is the biggest difference from ordinary concrete conveying pumps. This part should be focused on when cleaning.
First, use tools to scrape off concrete attached to the inner wall of the mixing chamber and the mixing blades. Then rinse continuously with water to wash away the loose slurry. Material can easily accumulate around the outlet, so you need to pay more attention to it.
The structure of the mixing chamber varies between models. Some use horizontal mixing systems, while others use vertical systems, so the cleaning procedures of other machines should not be copied directly. After all the flushing is completed, inspect the inside of the cavity to confirm that there are no large pieces of concrete piled up.
Step 2: Clean up the receiving hopper
The receiving hopper is the transition point for concrete to enter the pumping mechanism, and the hopper walls and grille will be covered with splashed mortar.
First, remove the concrete accumulated in the hopper, and then flush the walls and inlet grille inside the hopper. There will be pebbles and mortar stuck in the gaps of the grille. Simple flushing may not remove them completely. They can be removed with a brush.
The bottom of the hopper, as well as the transition area between the hopper and the pumping mechanism, is particularly prone to material buildup. If the concrete here hardens and clumps, the next time the material is fed, it will hinder the material from flowing into the pump body, which will directly affect feeding.
Step 3: Flush the pumping system
A lot of mortar will be left inside the pumping system and concrete delivery cylinders. Most of this residue is invisible to the naked eye, and external washing alone cannot reveal the problem. Before operation, read the instruction manual of the machine and rinse it according to the process given by the manufacturer. With different pumping structures, the sequence of flushing is not the same. Do not directly apply the operation experience of other models.
Generally, clean water is introduced, and the pumping action of the equipment helps flush residual mortar out of the cylinder. After the flushing, if possible, you can open the maintenance port after safely shutting down and depressurizing the equipment for a brief check to confirm that there is no residual slurry inside.
Step 4: Clean the concrete pipeline
In the whole conveying pipeline, especially at the elbows and joints, the mortar is most likely to accumulate.
According to the equipment configuration, choose the corresponding pipeline cleaning method. Construction sites commonly use reverse pumping, water flushing, or cleaning with a sponge ball. A water-soaked sponge cleaning ball can be used according to the manufacturer’s instructions. Reverse pumping can return residual concrete in the pipe to the hopper, while water pressure can push the sponge ball through the pipe in the conveying direction and out of the pipe outlet. This method can take away the mortar attached to the pipe wall and reduce the probability of subsequent pipe blockage.
When using a sponge cleaning ball, confirm that the size of the cleaning ball matches the inner diameter of the pipe. It is strictly forbidden to stand in front of the pipeline outlet. The cleaning ball is pushed out by water pressure at high speed, and the impact is great. If the outlet is directed toward personnel, it will cause a serious safety accident.
After completing the pipeline washing, do not disassemble the pipeline immediately. Wait until the internal pressure of the pipeline is completely released, and then disassemble it in sections to confirm that there is no concrete attached to the pipe wall.
Step 5: Rinse the outer surface of the equipment
At the operation site, concrete slurry often splashes on the frame, shell, chassis, tires and stabilizers. This slurry is difficult to remove after drying and hardening, so it should be rinsed off after each operation.
There is one thing that needs special attention when flushing the outside. The electric control box, all kinds of sensors and electrical joints should not be directly sprayed with a high-pressure water gun. High-pressure water seeps into the electrical connections, which will cause short circuits and component damage.
The mortar in the gaps around the chassis and stabilizers can be cleaned with low-pressure water flow and tools. After finishing everything, walk around the equipment to see if there are any remaining concrete spots on the exterior.
Common Cleaning Errors, Special Points of Diesel and Electric Mixing Pumps
Cleaning mistakes that need to be avoided
Don’t start cleaning when the concrete is about to harden. The concrete will gradually solidify after the mixing is completed. The longer the interval, the more difficult it is to clean up. When it is completely hardened, it may need to be removed by knocking and chiseling, which may also damage the inner wall of the equipment.
Many workers only clean the mixing chamber and ignore the pumping cylinders and conveying pipelines. The mixing chamber looks clean, but the inside of the pipeline is full of mortar. This can easily block the pipe during the next startup, and the whole cleaning effort is wasted.
Pipe cleaning can’t be done randomly. Choosing a cleaning ball with a mismatched size or skipping part of the rinsing process will not only result in incomplete cleaning but may also cause the cleaning ball to be stuck in the middle of the pipe, forming a new blockage.
It is also a common error to directly spray electrical components with high-pressure water. Even if the equipment has been shut down, water entering the wiring connections can create a risk of electrical leakage and short circuits.
Notes on the cleaning of diesel and electric concrete mixer pumps
Diesel concrete mixer pump:
- When flushing the periphery of the engine, avoid the engine air inlets and various electrical connectors, and do not let a large amount of water flow into these parts.
- The temperature of the engine and exhaust housing immediately after shutdown can be very high, and spraying a large amount of cold water directly onto them may damage the parts. Avoid the high-temperature surfaces when operating.
Electric concrete mixer pump:
- The main power supply must be cut off and isolated to eliminate the risk of electric shock during flushing.
- The water flow should not be directed toward the motor body, control cabinet and terminal block. After all the cleaning, check whether the electrical parts are wet or damp, and confirm that they are dry before storing.
In the two models, the cleaning procedures of the mixing and pumping chambers are basically the same, and the difference is mainly in protection against water and high temperatures around the power system.
Final Inspection Before the Next Power-On
The completion of the cleaning does not mean that all the work is completed. A quick and simple inspection before starting can avoid many sudden failures.
- Take a look inside the mixing chamber to confirm that there are no remaining concrete lumps and no residue in the receiving hopper and pumping cavity.
- Confirm that the whole conveying pipeline has been cleaned, and the pipe joints and sealing rings have not been damaged or displaced.
- All electrical parts should be kept dry and there should be no water stains. The shovels, brushes and cleaning balls used before should all be removed from the equipment and should not be left in the hopper or pipeline.
- All kinds of safety guards and protective covers should be installed back to their original positions. Before the next startup, the inspection requirements of the equipment manufacturer’s instructions shall still prevail.
- In winter or low-temperature working conditions, also confirm that the drainage points of the water system have been emptied, and there is no sign of water freezing inside the equipment. At the same time, check the grease levels of each lubrication point, and then return the equipment to operation.